SamplexPower EVO-RC-PLUS Owner's Manual page 71

Remote control for evolution series inverter/ charger
Table of Contents

Advertisement

SECTION 4 |
TABLE 4.5 (Continued) PARAMETER "CHARGING PROFILE" - OPTIONS FOR 3-STAGE / 2-STAGE CHARGING
Srl
Options under
No.
Programming Parameter
"CHARGING PROFILE"
5
4=2Stage Type2
6
5=2Stage Type3
4.4.2.21.1 Programming Steps for Parameter "CHARGING PROFILE"
Any Operating Mode Screen from
Fig 3.1 to 3.8
E V O - 1 2 1 2 F
I n v e r t i n g
A C
o u t p u t :
1 2 0 . 0 V
< 0 . 1 0 A
6 0 . 0 0 H z
[Above screen is Screen 1 of Fig 3.2(a)]
Parameter Setup
1. Stage 1 – Bulk Stage (For details, see Section 5.7.1.1 of the Owner's Manuals for
EVO
Series Inverter/Charger):
TM
Charge at constant current = the programmed value of parameter "BULK
CURRENT"
(For details of programming range & procedure, refer to Section 4.4.2.1
Transition to Absorption Stage when voltage rises to the set value for programming
parameter "ABSORP VOLTAGE"
4.4.2.2
2. Stage 2 - Absorption Stage (For details, see Section 5.7.2 of the Owner's Manuals
for EVO
Series Inverter/Charger:
TM
Charge at constant voltage = the programmed value for parameter "ABSORP
VOLTAGE".
(For details of programming range & procedure, refer to Section 4.4.2.2)
Remain in Absorption Stage
Reset to Bulk Stage under the following conditions:
i.
If the AC input fails or is switched off and is restored subsequently
ii. If battery voltage falls to the programmed value of parameter "RESET TO
BULK" .
(For details of programming range & procedure, refer to Section 4.4.2.15).
1. Stage 1 – Bulk Stage (For details, see Section 5.7.1.1 of the Owner's Manuals for
EVO
Series Inverter/Charger):
TM
Charge at constant current = the programmed value of parameter "BULK
CURRENT"
(For details of programming range & procedure, refer to Section 4.4.2.1
Transition to Absorption Stage when voltage rises to the set value for programming
parameter "ABSORP VOLTAGE"
4.4.2.2
2. Stage 2 - Absorption Stage (For details, see Section 5.7.2 of the Owner's Manuals
for EVO
Series Inverter/Charger):
TM
Charge at constant voltage = the programmed value for parameter "ABSORP
VOLTAGE".
(For details of programming range & procedure, refer to Section 4.4.2.2)
Remain in Absorption Stage till the current reduces to value = the programmed
value of parameter "ABSORP EXIT AMPS"
to Section 4.4.2.20)
Switch off charging after the current reduces to value = the programmed value of
parameter "ABSORP EXIT AMPS"
4.4.2.20)
Reset to Bulk Stage under the following conditions:
i.
If the AC input fails or is switched off and is restored subsequently
ii. If battery voltage falls to the programmed value of parameter "RESET TO
BULK" .
(For details of programming range & procedure, refer to Section 4.4.2.15).
Enter Key
S e l e c t
G r o u p
*
C H A R G E
C U R V E
ð
P a s s w o r d
k e y
0 0 0 0
Password 8052
See Section 4.3.1
Charging Stages
(For details of programming range & procedure, refer to Section
(For details of programming range & procedure, refer to Section
(For details of programming range & procedure, refer
(For details of programming range & procedure, refer to Section
Enter Key
S e l e c t
P a r a m e t e r
C H A R G E
ð
*
B U L K
C U R R E N T
2 0 A
Enter Key
i n
S e l e c t
P a r a m e t e r
C H A R G E
ð
*
C H A R G I N G
0 = 3 S t a g e
See Table 4.3, Parameter Setup
Screen No. 21 for
programmable options
Down Key x 20 times
S e l e c t
C U R V E
C H A R G E
ð
*
C H A R G I N G
0 = 3 S t a g e
C U R V E
P R O F I L E
A d a p t i v e
SAMLEX AMERICA INC. | 71
Battery Type
− Lithium (For details,
see Section 5.11 of
Owner's Manuals for
EVO
Series Inverter/
TM
Charger):
− Lithium (For details,
see Section 5.11 of
Owner's Manuals for
EVO
Series Inverter/
TM
Charger):
− Nickel Zinc (For details,
see Section 5.10 of
Owner's Manuals for
EVO
Series Inverter/
TM
Charger):
Enter Key
P a r a m e t e r
C U R V E
ð
P R O F I L E
A d a p t i v e

Advertisement

Table of Contents
loading