D-500 MK2 User Manual
3.6. CHARGE INPUT TERMINAL
The Charge terminal is both an input and output.
When the engine is ready to run, this terminal supplies the excitation current to the charge alternator.
The excitation circuit is equivalent to a 2W lamp.
The threshold voltages for warning and shutdown alarm are adjustable through program parameter.
Structure:
Output current:
Voltage measurement
resolution:
Voltage measurement
accuracy:
Charge Fail Warning
Threshold:
Charge Fail Shutdown
Alarm Threshold:
Open circuit voltage:
Overvoltage protection:
Reverse voltage
protection:
3.7. MAGNETIC PICKUP INPUT
Structure:
Input impedance:
Input voltage:
Max common mode
voltage:
Frequency range:
Resolution:
Accuracy:
Flywheel teeth range:
•
battery voltage output through 20 ohm PTC
•
voltage measurement input
160mA @12VDC
80mA @24VDC
0.1VDC
2% + 0.1V (0.9V @30VDC)
adjustable
adjustable
battery positive
> 500VDC continuous, with respect to battery negative
-30VDC with respect to battery negative
Differential frequency measurement input
50 k-ohms
0.5VAC-RMS to 30VAC-RMS
± 5VDC
10Hz to 10 kHz
1 rpm
0.2% + 1 rpm (±3rpm @1500 rpm)
1 to 500
Do not share MPU with other devices.
- 23 -
Firmware V-6.3