H-7 Trend Analysis Output 1
Usage:
Definition:
Example:
H-7-1
Trend Analysis Mode
Definition:
Serial Cmd:
Default:
Options:
Mismatch
Output will be activated when the number of mismatches equals the value entered for Number to
Output On within the trigger window selected in Number of Triggers.
No-Read
Output will be activated when the number of No-Reads equals the value entered for Number to
Output On within the trigger window selected in Number of Triggers.
Decodes per Trigger
Output will be activated when the number of decodes equals the value entered for Number to Output
On within the trigger window selected in Number of Triggers.
H-7-2
Trigger Evaluation Period
Definition:
Serial Cmd:
Default:
Options:
V440-F C-Mount Code Reader User Manual
Useful in cases where the user doesn't want to shut down for one condition
but wants to monitor quality and read conditions.
Applies Trend Analysis settings to Output 1.
With Trend Analysis, the user can track the occurrences and frequency of
mismatches, No-Reads, and the number of reads per trigger, and output the
results to any of three outputs.
Trend Analysis Mode = No-Read
Trigger Evaluation Period= 25 triggers (read cycles)
Number to Output On = 4
In this example, the reader will activate an output when 4 No-Reads occur
within a period of 25 triggers (read cycles).
Sets the trend condition (Mismatch, No-Read, or Decodes per Trigger) that
will activate the output.
<K780,trend analysis mode,trigger evaluation period,number to output on,
decodes per trigger threshold>
No-Read
0 = Mismatch
1 = No-Read
2 = Decodes per Trigger
The number of triggers to examine for the trend analysis condition.
<K780,trend analysis mode,trigger evaluation period,number to output on,
decodes per trigger threshold>
0
0 to 255
Appendices
H
H-11