8 Advanced Settings
Examples
The following section provides examples of how to configure the custom Ethernet object using the
Custom Ethernet Link K Command <K166> described in the Configuration section earlier in this
topic.
 TCP
Server Mode
Send/Receive Capabilities
<K166,1,0,0,3>
Interpretation of K Command Settings: Custom Ethernet Link Enabled Default, Transport Layer =
TCP Default, Type = Server Default, Capabilities = Send/Receive Default
Send-Only Capabilities
<K166,1,0,0,2>
Interpretation of K Command Settings: Custom Ethernet Link Enabled Default, Transport Layer =
TCP Default, Type = Server Default, Capabilities = Send
Client Mode
The following client modes will connect to a TCP Server with IP Address 192.168.188.5 listening on
port 5050.
Send/Receive Capabilities
<K166,1,0,1,3,192.168.188.5, ,5050>
Interpretation of K Command Settings: Custom Ethernet Link Enabled Default, Transport Layer =
TCP Default, Type = Client, Capabilities = Send/Receive Default, IP Address = 192.168.188.5, Port =
8
5050.
Send-Only Capabilities
<K166,1,0,1,2,192.168.188.5, ,5050>
Interpretation of K Command Settings: Custom Ethernet Link Enabled Default, Transport Layer =
TCP Default, Type = Client, Capabilities = Send, IP Address = 192.168.188.5, Port = 5050.
 UDP
Server Mode
Send/Receive Capabilities
<K166,1,1,0,3>
Interpretation of K Command Settings: Custom Ethernet Link Enabled Default, Transport Layer =
UDP, Type = Server Default, Capabilities = Send/Receive Default.
Send-Only Capabilities
<K166,1,1,0,2>
Interpretation of K Command Settings: Custom Ethernet Link Enabled Default, Transport Layer =
UDP, Type = Server Default, Capabilities = Send.