G-18 Composite
When set to Enabled or Required, will decode the 2D composite component of a linear symbol. The
linear symbol can be DataBar-14, DataBar Expanded, DataBar Limited, EAN-128, UPC-A, EAN-13,
EAN-8, and UPC-E.
Usage:
Definition:
Serial Cmd:
Default:
Options:
Enabled
If Composite is set to Enabled, the reader will decode both the 2D composite and linear components.
However, if the 2D composite component is not decoded, the linear data will be sent by itself at the end
of the read cycle.
Required
If set to Required, the reader must decode both components, or a No-Read will occur.
G-18-1 Separator Status (Composite)
Usage:
Definition:
Serial Cmd:
Default:
Options:
G-18-2 Separator Character (Composite)
• Note: The Separator Character will be the same as the character defined in the Multisymbol Separator field of the
<K222> command.
Usage:
Definition:
Serial Cmd:
Default:
Options:
V440-F C-Mount Code Reader User Manual
Allows reading by both linear and 2D readers.
Combines 2D and linear width-modulated symbology on the same symbol
where different messages can be read by each reader type.
<K453,mode,separator status,separator>
Disabled
1 = Enabled
0 = Disabled
Allows the user to distinguish between the main and Supplemental symbols.
Separates the linear and the composite component.
<K453,mode,separator status,separator>
Disabled
1 = Enabled
0 = Disabled
As required by the application.
Allows the user to change the separator character from a comma to a new
character.
<K453,mode,separator status,separator>
, (comma)
Any ASCII character.
Appendices