Appendices
H-1 I/O Parameters Serial Commands
Power On/Reset Counts
Time Since Reset (Read-Only)
Service Message
User-Defined Name
Serial Verification
Quality Output
Symbol Data Output
Read Duration Output
No-Read Message
Output Object Info
Database Identifier Output
Image Push to Host
Image Push to Host Detail Setup <K763,Image Storage Location,FTP Host Info,Transfer
Trend Analysis Output 1
Trend Analysis Output 2
Trend Analysis Output 3
Diagnostic Output 1
Diagnostic Output 2
Diagnostic Output 3
ISO/IEC 16022 Symbol Quality
Output 1
ISO/IEC 16022 Symbol Quality
Output 2
ISO/IEC 16022 Symbol Quality
Output 3
Output 1 Parameters
Output 2 Parameters
Output 3 Parameters
ISO/IEC 15415 Symbol Quality
Output 1
H-2
<K406,power-on,resets,power-on saves,customer
default saves>
<K407,hours,minutes>
<K409,status,service message,threshold,resolution>
<K412,user-defined name>
<K701,serial command echo status,control/hex output>
<K704,quality output separator,decodes per trigger
status>
<K705,status,when to output,symbology identifier
status>
<K706,status,separator>
<K714,status,message>
<K734,output frame number status,output coordinates
status>
<K759,status,separator character>
<K764,Image Storage Status,Stored Image Type,Image
Storage, Image File Format,Image Quality,Image
Scale,File Save Options>
Optimization, RAM Drive Size in MB,Save Image
Until,Action at Image Storage Limit>
<K780,trend analysis mode,number of triggers,number
to output on,decodes per trigger>
<K781,trend analysis mode,number of triggers,number
to output on,decodes per trigger>
<K782,trend analysis mode,number of triggers,number
to output on,decodes per trigger>
<K790,service unit message status>
<K791,service unit message status>
<K792,service unit message status>
<K800,output on symbol contrast,symbol contrast
threshold,output on print growth,print growth
threshold,output on axial non-uniformity, axial non-
uniformity threshold,output on Unused ECC,Unused
ECC threshold>
<K801,output on symbol contrast,symbol contrast
threshold,output on print growth,print growth
threshold,output on axial non-uniformity, axial non-
uniformity threshold,output on Unused ECC,Unused
ECC threshold>
<K802,output on symbol contrast,symbol contrast
threshold,output on print growth,print growth
threshold,output on axial non-uniformity, axial non-
uniformity threshold,output on Unused ECC,Unused
ECC threshold>
<K810,output on,output state,pulse width,output mode>
<K811,output on,output state,pulse width,output mode>
<K812,output on,output state,pulse width,output mode>
<K870,Output on Overall Grade, Overall Grade
Threshold, Symbol Contrast, Symbol Contrast
Threshold, Modulation, Modulation Threshold,
Reflectance Margin, Reflectance Margin Threshold,
Fixed Pattern Damage, Fixed Pattern Damage
Threshold, Axial Nonuniformity, Axial Nonuniformity
Threshold, Grid Nonuniformity, Grid Nonuniformity
Threshold, Unused ECC,Unused ECC Threshold>