Omron V440-F User Manual page 319

C-mount code reader
Table of Contents

Advertisement

Appendices
G-9-4 Symbol Length #2 (Interleaved 2 of 5)
Usage:
Definition:
Serial Cmd:
Default:
Options:
G-9-5 Guard Bar Status (Interleaved 2 of 5)
• Note: Whenever Guard Bar is enabled, the presence of guard bars (also called "bearer bars") is required for decoding
to take place.
Usage:
Definition:
Serial Cmd:
Default:
Options:
G-9-6 Range Mode Status (Interleaved 2 of 5)
Usage:
Definition:
Serial Cmd:
Default:
Options:
G-14
Useful in applications where I 2/5 symbols of a specific length are
required.
The Symbol Length # 2 field is one of two fields against which the
decoded symbol is compared before accepting it as valid or rejecting it.
<K472,status,check character status,check character output,symbol length
#1,symbol length #2,guard bar status,range mode status>
6
0 to 64, even only
Important: If Range Mode is disabled, the length of the symbol must
match either Symbol Length # 2 or Symbol Length # 1 to be considered
a valid symbol.
If Range Mode is enabled, Symbol Length # 2 and Symbol Length # 1
form a range into which the length of the symbol must fall to be considered
valid.
Useful when I-2/5 multisymbols are enabled to prevent false data output.
This typically occurs with highly tilted or skewed symbols.
A guard bar is a heavy bar, at least twice the width of the wide bar, surrounding
the printed I-2/5 symbol and helping to prevent false reads.
<K472,status,check character status,check character output,symbol length
#1,symbol length #2,guard bar status,range mode status>
Disabled
1 = Enabled
0 = Disabled
Useful in applications where I 2/5 symbols of a specific length are required.
When Range Mode is disabled, the reader checks the value of the symbol
length against the values set in Symbol Length # 1 and Symbol Length #
2. If the symbol length does not match either of the preset values, then it is
rejected as invalid.
When Range Mode is enabled, Symbol Length # 1 and Symbol Length #
2 are combined to form a range of valid symbol lengths. Any symbol length
that does not fall into this range is rejected as an invalid symbol. Either of
the preset symbol length values in the Symbol Length # 1 and Symbol
Length # 2 fields can form the start or end of the range.
<K472,status,check character status,check character output,symbol length
#1,symbol length #2,guard bar status,range mode status>
Enabled
0 = Disabled
1 = Enabled
V440-F C-Mount Code Reader User Manual

Advertisement

Table of Contents
loading

Table of Contents