Omron V440-F User Manual page 317

C-mount code reader
Table of Contents

Advertisement

Appendices
G-8 BC412
Usage:
Definition:
Serial Cmd:
Default:
Options:
G-8-1 Check Character Output (BC412)
Usage:
Definition:
Serial Cmd:
Default:
Options:
G-8-2 Fixed Symbol Length Status (BC412)
Definition:
Serial Cmd:
Default:
Options:
G-8-3 Fixed Symbol Length (BC412)
Definition:
Serial Cmd:
Default:
Options:
G-12
Widely used in semiconductor manufacturing. Particularly useful where
speed, accuracy, and ease of printing are required.
BC412 (Binary Code 412), a proprietary IBM symbology since 1988, is an
alphanumeric symbol with a set of 35 characters, each encoded by a set of
4 bars in 12 module positions. All bars have a single width; it is the presence
(1) or absence (0) of bars in each of the twelve module positions that make
BC412 binary.
This symbology is also bi-directional and self-clocking, with a start character
and a stop character.
<K481,status,check character output,fixed symbol length status,fixed symbol
length>
Disabled
1 = Enabled
0 = Disabled
Check Character Output, added to the symbol, provides additional
security.
When enabled, the check character is read and compared along with the
symbol data. When disabled, symbol data is sent without the check charac-
ter.
<K481,status,check character output,fixed symbol length status,fixed
symbol length>
Disabled
1 = Enabled
0 = Disabled
When enabled, the reader will check the symbol length against the symbol
length field. If disabled, any length will be considered valid.
<K481,status,check character output,fixed symbol length status,fixed
symbol length>
Disabled
1 = Enabled
0 = Disabled
When enabled, the check character is read and compared along with the
symbol data. When disabled, symbol data is sent without the check charac-
ter.
<K481,status,check character output,fixed symbol length status,fixed
symbol length>
10
1 to 64
V440-F C-Mount Code Reader User Manual