Cycle - Omron V440-F User Manual

C-mount code reader
Table of Contents

Advertisement

4-3

Cycle

4-3-1
Introduction
The reader can operate in a number of modes from a continuous reader to a triggered reader. The
Cycle determines how the reader will operate. Setting up the read cycle type and parameters will
involve a series of decisions based on your particular application:
1
Select the cycle type. The choices are either the free-running Continuous Mode or one of the
various triggered modes: Triggered, Start/Stop, or Custom.
2
Select the number of symbols (either 1D or 2D codes, depending on your application) to
be decoded in a single cycle. The reader can satisfy this condition by reading one or more
symbols in a single image frame or across multiple image frames. The reader will communicate
pass if it finds all symbols, and fail if it does not. Note that the reader will not read and count a
symbol if it is the same code type and contains the same data as a previous code.
3
Choose whether or not to allow the reader to read duplicate codes and to include them as
symbols found and as part of the output data.
4
Decide how the cycle will start by choosing the trigger type to be used. If free-running, the reader
will start automatically. If triggered, you must select Serial Trigger and choose a serial character
for the trigger, or if through I/O, you must choose either the External Level or External Edge
Trigger Mode.
Note: Use
5
Designate how the read cycle should end: Good Read, Timeout, New Trigger, or Last Frame.
6
Select the Capture Mode – either Continuous or Rapid Capture.
7
If in Rapid Capture, select the Number of Captures, and the modes Timed Capture or Triggered
Capture.
8
If Timed Capture, set the Time Before First Capture and Time Between Captures, if any.
4-3-2
Common Settings for all Cycle Modes
The following four settings are common settings for all read cycle modes:
Look for # Codes – This is the number of codes that the reader should find in each decode cycle. If the
reader finds all codes, the decode cycle will pass. If it does not find all codes, the cycle will fail and only
the codes it finds will be output. The remaining codes will be listed as No Read. This value can be set
from 1 to 400, but 70 is typically a practical limit in an average complex scene. This is because the
algorithm is limited by the overall number of edge candidates that it can process. In this case it is
recommended that you use Matrix Mode or multiple ROIs to surpass this practical limit.
Timeout After – This is the amount of time the reader is allowed to spend for the entire read cycle,
acquiring and processing images until all codes are read. You should set this value long enough to be
able to decode in all circumstances, but short enough to prevent the reader from taking longer than the
allowed cycle time of the production line. This value can be set from 10 milliseconds to 65 seconds
(655,350 ms).
Allow Duplicates – The check box tells the reader what to do if it finds codes with the same content.
By default, the reader will ignore duplicate codes. It will not count them as one of the codes it is set to
find, and it will not include them in the output string data. If Allow Duplicates is checked, duplicate codes
will be counted and included as part of the output string.
Configuration Database – Enable or disable the Configuration Database as part of the read cycle.
The Configuration Database is described in detail in Setup > Configuration Database.
The different cycle modes are explained in detail below.
V440-F C-Mount Code Reader User Manual
or
Cycle > Custom
Advanced Settings > Read Cycle
4 Setup
to set the Trigger Mode.
4-9
4

Advertisement

Table of Contents
loading

Table of Contents