Operational Commands - Omron V440-F User Manual

C-mount code reader
Table of Contents

Advertisement

Appendices
M-1 Operational Commands
Type
Counter
Request/Clear
Firmware Verifica-
tion
Read Rate
Device Control
Read Cycle
Enable/Disable
Parameter
Reset/Save
Resets
M-2
Command
No-Reads Per Read Cycle Counter
<q>
No-Reads Per Read Cycle Counter Reset
<q0>
Mismatch Per Read Cycle Counter
<$>
Mismatch Per Read Cycle Counter Reset
<$0>
No-Read Counter
<N>
No-Read Counter Reset
<O>
Trigger Counter
<T>
Trigger Counter Reset
<U>
Match Code Counter
<V>
Match Code Counter Reset
<W>
Mismatch Counter
<X>
Mismatch Counter Reset
<Y>
Request All Part Numbers
<#>
Request Application Firmware Part Number
<#a>
Request Boot Code Firmware Part Number
<#b>
Request All Firmware Checksums
<!>
Request Application Firmware Checksum
<!a>
Request Boot Code Firmware Checksum
<!b>
Request Current Parameter Settings Check-
<!s>
sum
Decodes Per Second Test
<C>
Decode Percent Test
<Cp>
Exit Read Rate Tests
<J>
Preface PDF417 Output with Data Attributes
<a1>
Pulse Programmable Output 1
<L1>
Pulse Programmable Output 2
<L2>
Pulse Programmable Output 3
<L3>
End Current Read Cycle until <H>
<I>
Enable Read Cycle after <I>
<H>
Activate Targeting System
1
<l1>
Deactivate Targeting System
2
<l0>
Complete Reset when Resets or Save for
<A?/1>
Power-On Command Has Been Issued
Warm Reset if Power-On Command Has
<A?/0>
Been Issued
Software Reset, Current Parameters
<A>
Retained
Software Reset, Recall Default Parameters
except Communication and Custom Unit
<Ard>
Name Parameters
Software Reset, Recall Power-On Default Parameters
<Arp>
Software Reset, Recall Customer Default
<Arc>
Parameters
1
<l1> = lowercase 'L', one
2
<l0> = lowercase 'L', zero
Name
V440-F C-Mount Code Reader User Manual

Advertisement

Table of Contents
loading

Table of Contents