4 Setup
Mode Types
Clicking the database entry icon for any given database entry allows you to change the Configuration
Database mode.
There are three Configuration Database modes:
• Standard Mode – This mode is a general symbology tool. It can be used to decode any number
of symbols within the region of interest.
• Matrix Mode – In this mode, the Configuration Database entry is decoding a matrix as defined by
the Matrix Mode setup tool. There can only be one matrix defined for the system, but multiple
database entries can be used for the one matrix so you can vary all the standard image and
decode variables as you would for an individual symbol. The system works its way through all
entries until all codes in all cells are decoded. The system then compiles these into a single result.
• Unique ID Mode – This is also a general symbology tool, but is typically used to label one partic-
ular symbol with a unique identifier. Labeling individual codes is a very useful tool when setting up
Formatted Output with a particular output order.
Note: Unique ID labels must not be included in other Window of Interest WOI or Matrix Mode cells.
Switching to Simple Mode will do the following:
• Force the system to Region of Interest ROI Mode;
• Attempt to group Database Indexes into image captures;
• Turn every Capture Index off;
• Prompt you to click CONTINUE or CANCEL.