SECTION 6
6.0.10 Temperature Status Register
Figure 3 shows the Temperature Status Register. It also takes the standard SCPI structure.
Output Board Over-Temperature
The output board temperature surpasses its allowed operating limit.
Primary Board Over-Temperature
The primary board temperature surpasses its allowed operating limit.
Fan Stall
The cooling fan is non-operative.
SCPI Access
Access to the Temperature Status Register is via the following commands:
STATus:QUEStionable:TEMPerature[:EVENt]?
STATus:QUEStionable:TEMPerature:CONDition?
STATus:QUEStionable:TEMPerature:ENABle <value> Set Enable register
STATus:QUEStionable:TEMPerature:ENABle?
STATUS AND ERRORS
Figure 3: Temperature Status Register
iLS600, iLS600-R and iLS1500 Series
Rev. 05.20.21_#1.0
Rtn Event register
Rtn Condition register
Rtn Enable register
advancedenergy.com