SCPI Commands

*CLS
— This command clears the following registers:
The Standard Event Status Register
The Event register of the Questionable Status Register structure.
The Event register of the Operation Status Register structure.
The Event register of the Temperature Status Register (a part of the Questionable
Status Register structure).
The Event register of the Hardware Status Register (a part of the Questionable
Status Register structure).
The Error/Event Queue.
*ESE <value>
— This command sets the Standard Event Status Enable Register to the
specified value. The value is specified in decimal form with the following value assignments:
1
Operation Complete
2
Request Control (not used)
4
Query Error (not used)
8
Device-Specific Error – Set for:
Calibration Error
Error Queue Overflow
Hardware Error
Output Error
Over-Voltage Condition
Over-Current Condition
Over-Power Condition
Self-Test Error
 12V Bias Error
 3.3V Bias Error
 PFC Failure Pending
 PFC Failure
iLS600, iLS600-R and iLS1500 Series