APPENDIX
SYSTem:MODe:ASCale?
level of the specified analog channel (voltage or current).
SYSTem:ERRor:CLEar
SYSTem:ERRor:CONDition?
Contents consist of:
1
2
4
8
16
32
64
128
256
512
1024
2048
32768
If multiple bits are set, the result is the sum of the set bit values.
SYSTem:ERRor:COUNt?
Errors/Events Queue.
SYSTem:ERRor[:NEXT]?
Errors/Events Queue. This results in both the Error number and text string being returned.
— This command returns the presently selected scaling
— This command clears the Error/Event Queue.
— This command returns the present Error Conditions state.
Over-Current Error
Over-Voltage Error
Over-Power Error
Output Board Over-Temperature Error
Fan Stall Error
Output (loss of regulation) Error
12V Bias Error
3.3V Bias Error
Primary (input) Board Temperature Error
PFC Failure
Watchdog Error
Self-Test Error
PFC Failure Pending
— This command returns the number of Errors/Events in the
— This command returns the next Error/Event in the
iLS600, iLS600-R and iLS1500 Series
Rev. 05.20.21_#1.0
advancedenergy.com
52