SECTION 6
Output Activated
This is the indication that the output is currently activated.
Constant Voltage
The output is in its constant voltage mode, where voltage is held constant at a specified
setpoint and current will vary dependent on load.
Constant Current
The output is in its constant current mode, where current is held constant at a specified
setpoint and voltage will vary dependent on load.
Constant Power
The output is in its constant power mode, where power is held constant at a specified
setpoint and voltage/current will vary dependent on load.
SCPI Access
Access to the Operation Status Register is via the following commands:
STATus:OPERation[:EVENt]?
STATus:OPERation:CONDition?
STATus:OPERation:ENABle <value>
STATus:OPERation:ENABle?
STATUS AND ERRORS
iLS600, iLS600-R and iLS1500 Series
Rtn Event register
Rtn Condition register
Set Enable register
Rtn Enable register
Rev. 05.20.21_#1.0
advancedenergy.com
27