SECTION 1
1.2 Remote Mode
In Remote Mode, you will control BENCH iLS using SCPI commands. You will also have
limited control available via the front panel
1.2.1 SCPI Commands
In the following list of available SCPI commands,
OUTPut <ON|OFF>
OUTPut?
VOLTage <value|MIN|MAX>
VOLTage?
CURRent <value|MIN|MAX>
CURRent?
POWer< value|MIN|MAX >
POWer?
MEASure:VOLTage?
MEASure:CURRent?
VOLTage:PROTect <value>
VOLTage:PROTect?
CURRent:PROTect <value>
CURRent:PROTect?
POWer:PROTect <value>
POWer:PROTect?
OUTPut:AUTOstart <ON|OFF>
OUTPut:AUTOstart?
SYSTem:CONFiguration:SAVE
1.2.2 Front Panel Commands
When in Remote Mode, you will have limited control from the front panel. Specifically, the
Enable button is available to deactivate the output when the output is ON or to enter
System Setup to switch to a different Operating Mode when the output is OFF.
OPERATING MODES
iLS600, iLS600-R and iLS1500 Series
Activate/deactivate output
Query activation state
Set voltage setpoint (value in volts)
Query voltage setpoint (volts)
Set current setpoint (value in amps)
Query current setpoint (amps)
Set power setpoint (value in watts)
Query current setpoint (watts)
Measure and return output voltage (volts)
Measure and return output current (amps)
Set voltage protection level (volts)
Query voltage protection level (volts)
Set current protection level (amps)
Query current protection level (amps)
Set power protection level (watts)
Query power protection level (watts)
Enable/disable the Auto-Start feature
Query present Auto-Start state
Save configuration data to non-volatile memory
Rev. 05.20.21_#1.0
advancedenergy.com
9