4.19 Troubleshooting Guide
The items included in this section cover the common causes of trouble that an operator might encounter
during the operation of the T-1000-S14. When operating difficulties occur, the best procedure is to
observe what is happening, identify the causes and effect the correction. Make only one adjustment at a
time, checking the results of each adjustment. If an adjustment does not help or escalates the problem(s),
return the settings back to the former position.
CAUTION: These tests and repairs should be performed only by qualified mechanics or electricians
and at their own risk.
Note: When troubleshooting a T-1000-S14 functioning within a system (i.e. with conveyors, scales,
feeders, counters, etc.), always isolate the equipment and operate each machine individually.
4.20 Troubleshooting Checklist
PROBLEM
60 Day Trial Expired screen
appears
Bags not tearing off
Low Battery screen appears
Touch screen does not display
No main power light
Pressure bar does not move
when foot switch is operated
Pressure bar moves inward but
does not reach the front plate
(retracts immediately)
POSSIBLE CAUSE
60 Day Trial expired
1. Continuous Strip is ON
2. Reverse Distance is too low
3. Reverse Speed too low
It is recommended to replace
battery once every three years.
1. Power off
2. Loose connection
3. Fuse blown
4. Contrast out of adjustment
1. Blown fuse
2. Bulb out
1. Disconnected air line/foot
switch
2. Power off
1. Anti-jam improperly
adjusted
2. Misalignment of guide rods
3. Insufficient air pressure
4. Loose / broken ground wire
on guide rods
CORRECTIVE ACTION
Call APPI Service
1. Turn Continuous Strip OFF
2. Increase Reverse Distance
3. Increase Reverse Speed
If the Low Battery Screen displays
on the touch screen, DO NOT turn
off the machine, it will erase the
operating program and any stored
settings. Call APPI Service to
reorder battery and for
replacement instructions.
1. Plug in power cord / turn on
2. Tighten connections
3. Replace fuse(s)
4. Adjust screen contrast
1. Replace fuse
2. Replace bulb
1. Hookup air line
2. Turn on power
1. Adjust anti-jam (section 4.12)
2. Align guide rods (section 4.6)
3. Increase air pressure
4. Connect / tighten ground wires
80