Page 109
4.12 PTFE Adjustment An anti-stick sheet which prevents the bag from sticking to heater bar surfaces is located immediately behind the front plate. The sheet should periodically be inspected for wear or damage. If holes or tears exist, the rolls can be turned (rotated) to cover the contact surfaces with fresh material.
4.17 Pressure Bar (Rubber) Replacement Located along the inside of the pressure bar is a strip of rubber, held on the pressure bar by a channel, pressing on the edges of the rubber. The rubber compresses against the front (gripper) plate holding the bag in place during sealing and during bag tear off.
4.20 Replace Thermocouple Wire A thermocouple wire brazed to a ring terminal and secured to the top of the upper heater bar, detects the amount of heat the heater bar is emitting. The thermocouple wire is considered a normal wear item and will infrequently fail, requiring replacement. To determine if the thermocouple is bad, follow these trouble-shooting steps: 1) Locate the "E13"...