Blower OFF: To preserve compressed air, the blower (air knife) will turn off after this preset amount of time has
passed. The value is set in minutes and fractions of a minute. For instance, a setting of 5.1 would turn the air off if
the machine is not in use for a period of five minutes and six seconds. A typical value is between three and five
minutes.
TempRange: The temperature range above and below the Seal Temperature set point the heater bar must reach
for the T-1000-S14 to operate fully. For example, if the Seal Temperature is set to 360°F(182.2°C) and the Temp
Range is set to 10° , the temperature would be within the acceptable range if the heater bar temperature was
between 350°F and 370°F (176.6°C and 187.7°C). If the temperature is within the acceptable range, the bagger
will display "Ready" and the T-1000-S14 can begin normal operation. If the temperature is out of this range, the
bagger will display "Waiting" and the T-1000-S14 will only be able to cycle in Setup mode. To change this
setting, press the <Temp Range> button, enter a value on the numeric keypad and press the <ENT> button. A
suggested setting for Temperature Range is 20°.
Feed Dist: The bag length distance, in inches, the perforation sensor does not look for a perforation in the bag
when the machine is indexing the bag. To change this setting, press the <Feed Dist> button, enter a value on the
numeric keypad and press the <ENT> button.
Seal Delay: The amount of time, in seconds, before the seal operation begins after the air is turned off. This delay
setting allows air to escape the bag. To change this setting, press the <Seal Delay> button, enter a value on the
numeric keypad and press the <ENT> button.
Cool Time: The amount of time, in seconds, the pressure bar is released to ensure the seal is cool enough to be
torn off after the pressure bar and heater bar have come in contact with the bag. To adjust this setting, press the
<Cool Time> button, enter a value on the numeric keypad and then press the <ENT> button.
IndexDelay: The amount of time, in seconds, the previous bag has to exit the seal area after it is released and the
next bag is fed into place. This delay prevents the next bag from feeding and prevents the seal bar from coming
into contact with the previous bag and causing a bag jam. To change this setting, press the <Index Delay> button,
enter a value on the numeric keypad and press the <ENT> button.
Feed Error: The amount of acceptable variation, in inches, from the set bag length. For example, if the bag
length is 15" and the Feed Error is set to 3", bags with 12-18" lengths would be accepted, but bags with a length
of 19" would cause operation to stop and an error message would be displayed. To change this setting, press the
<Feed Error> button, enter a value on the numeric keypad and press the <ENT> button.
Reverse Delay: The amount of time, in seconds, after the bag has been filled and sealed before the bag is
reversed. To change this setting, press the <Rev. Delay> button, enter a value on the numeric keypad and press
the <ENT> button.
Reverse Speed: The speed, in inches per second, at which the bagger reverses to separate the bag at the
perforation. To change this setting, press the <Reverse Speed> button, enter a value on the numeric keypad and
press the <ENT> button.
Twin Seal: The pressure bar seals for the first time then reverses and seals the bag a second time, below the first
seal. Press the green button to access the numeric keypad and set the distance between Twin Seals. A typical
distance is ¼".