Vertical Terminations - Rigid/Flex Pipe 127mm x 203mm

The minimum components required for a basic vertical termination are:
1
Vertical Termination Cap
1
Rigid Pipe Adaptor (Dura Vent only)
1
Length of pipe to adequately penetrate roof
1
Flashing (as required per AS/NZS 5601-2013, to be supplied
by installer).
Wall thickness is measured from the back standoffs to the inside
mounting surface of the termination cap. For siding other than vn=inyl
furring strips may be used, instead of the vinyl siding standoff, to
create a level surface to mount the vent terminal. The terminal must
not be recessed into the wall cladding. Measure the wall thickness
including the wall cladding.
Roof Pitch
flat to 7/12
over 7/12 to 8/12
over 8/12 to 9/12
over 9/12 to 10/12
over 10/12 to 11/12
over 11/12 to 12/12
over 12/12 to 14/12
over 14/12 to 16/12
over 16/12 to 18/12
over 18/12 to 20/12
over 20/12 to 21/12
WARNING:
Do not combine venting components from different venting systems.
However use of the the AstroCap
Meters
0.61
0.61
0.61
0.76
0.99
1.22
1.52
1.83
2.13
2.29
2.44
is acceptable with all systems.
TM
Vertical Terminal
Flashing
(not supplied)
Pipe Length
Rigid Pipe Adapter
(Use only with Simpson Dura Vent)
*Unit is not exactly as shown.
City Series ACV60E | 47