Framing Dimensions - Regency Fireplace Products City ACV60E Owners & Installation Manual

Table of Contents

Advertisement

Framing Dimensions

installation
NOTE: Framing may be constructed of combustible material (I.e. 2 x 4) and does not require steel studs.
Framing Dimensions CV60E
Framing
Description
Dimensions
NOTE: Framing may be constructed of combustible material (ie. 2 x 4)and does not require steel studs.
A
Framing Height
B*
Framing Width
Framing
Dimensions
C*
Framing Depth
A
D
Minimum Height to Combustibles
B
E
Corner Wall Depth
C
F
Corner Facing Wall Depth
D
E
G
Vent Centerline Height
F
I
Gas Connection Opening Height
G
J
Gas Connection Height
I
K
Gas Connection Inset-Centre Opening
J
L
Gas Connection Opening Width
K
L
** See manual for alternate Gas/ Electrical connection options
The lift handles add approximately 102mm to the width of the appliance. If the appliance will be lifted off the ground and slid into the framed opening, we sug-
With the lift handles adding approximately 4 inches to the overall width of the appliance,In cases where the appliance would need
gest changing the framing width from 1168mm to 1770mm to allow the appliance to slide into position with the handles on, or creating a platform in front of
in order to slide it into the framed opening, it is suggested that either the framing width change 65 11/16 to 69 11/16 "
position with the handles remaining on the appliance, or alternatively create a platform in front of the framed opening where the lift handles could be removed
the framed opening where the lift handles can be removed prior to installation. If the framing is raised off the ground you can install it after the appliance is in
prior to sliding the appliance into its final position. Alternatively, If raised o the ground, the framing could be installed afterwards once appliance has been
place with handles removed to maintain the framing width of 1668mm. Ensure that the wood base for the appliance is strong enough to support its shipping
put into place and handles removed in order to keep framing width at 65 11/16".. Ensure that the wood base that the appliance will sit on is strong enough
weight of 210kg.
to support the full weight of this appliance. The overall weight of this appliance is 480 pounds (shipping weight).
Note: A combined minimum
of 180 square inches of open
area is required for the con-
vection air outlet to cool the
Note: A combined minimum of
enclosure. Ensure clearances
1168 square cm of open area
for Convection Air Outlets
is required for the convection
are met.
air outlet to cool the enclosure.
See clearances CV60E in this
Ensure clearances for convec-
manual as there are di erent
methods as to how this can
tion air outlets are met.
be achieved.
See clearances in this manual
for different ways to achieve
this.
Note: This appliance must be
Note: This appliance must be
installed on a solid surface
installed on a solid surface
such as a plywood floor
such as a plywood
which must be the full width
which must be the full width
and depth of the appliance.
and depth of the appliance.
|
* The framing depth/width does not take into account plasterboard/wood or similar materials against the back /side wall.
The framing depth will need to change based on the thickness of the material.
Example: B - 65 11/16" framing width +13 mm plasterboard per side = 66 11/16")
Example: C - 20 5/16" framing depth +13 mm plasterboard = 20 13/16")
Description
Framing Height
Framing Width
Framing Depth
Minimum Height to Combustibles
Corner Wall Depth
Corner Facing Wall Width
Vent Centerline Height
Gas Connection Opening Height
Gas Connection Height
Gas Connection Inset-Centre Opening
Gas Connection Opening Width
oor
City Series CV60E
ACV60E
1137 mm
1668 mm
CV60E
516 mm
44 3/4" (1137mm)
2038 mm
65 11/16" (1668mm)
1866 mm
20-5/16" (516mm)
2638 mm
81 1/4"(2038mm)
73 7/16" (1866mm)
1478 mm
103 7/8" (2638mm)
See gas connection location in this manual
58 3/16" (1478mm)
See gas connection location in this manual
See gas connection location in this manual
See gas connection location in this manual
See gas connection location in this manual
See gas connection location in this manual
See gas connection location in this manual
See gas connection location in this manual
*
installation
to be raised o the ground
so appliance could be easily slid into
*
City Series ACV60E | 31

Advertisement

Table of Contents
loading

This manual is also suitable for:

City acv60engCity acv60elpCity acv60eulpg