Glass Barrier Adjustment

Glass Barrier Adjustment
Glass barrier adjustment
If glass isn't hanging straight, use a phillips screwdriver to adjust the angle.
Clockwise = angles barrier out toward you
Counter clockwise = angles barrier in towards the unit.
Slide the screwdriver straight up at the two indicator slots.

AERATION ADJUSTMENT

The burner aeration is factory set but may need adjusting due to either the local gas supply or
altitude. Open the air shutter for a blue flame or close for a yellow flame.
Minimum Air Shutter Opening:
Natural Gas:
5mm
Propane:
9.5 mm
ULPG:
Full Open
Note: Any damage due to carboning resulting from improperly setting the aeration controls
is NOT covered under warranty.
installation
City Series ACV60E | 59