OPTIONAL FAN DUCTING KIT INSTALLATION
Note: ACB40E/ACC40LE/ACC40RE/ACV40AC - The 656-995 HeatWave adapter and 946-596 Aluminum flex (4.5m) must be purchased separately.
ACB60E/ACV60E - The 946-766 HeatWave adapter and 946-596 Aluminum flex (4.5m) must be purchased separately.
LISTINGS AND CODE
APPROVALS
This Fan Kit has been approved for use with ACV40E
/ACB40E/ACC40LE/ACC40RE/ACB60E/ACV60E.
NOTE: ENERGY LABEL RATINGS DO NOT
REFLECT INSTALL OF OPTIONAL FAN KIT.
Check with your local building code agency before
you begin installation to ensure compliance with local
codes, including the need for permits and follow-
up inspections. If any problems are encountered
with code approvals, or if you need clarification on
any of these instructions, contact your local dealer.
Ceiling
Register
Wall
Register
Ceiling
Register
Wall
Register
Diagram 1: Guide for possible air duct runs
and locations. Keep duct length and number of
bends to a minimum. Maximum duct length is
9.0 m.
The Flexible Duct (946-596) contains a maxi-
mum of 4.5 m. Please purchase another Flexible
Duct (946-596) to increase to 9.0 m.
Item No.
Description
No
1
240V Fan As-
7
sembly
2
Duct Flange-
Fan
3
Adapter Round
8
to Oval
4
Angle Bracket
9
5
Junction Box
10
6
Wall Adapter
Plate
NOTE: The fan kit (946-591) does not contain
any ducting. The optional extension duct kit (7
in the noted table) is 4.5 metres in length (part
number 946-596).
920-347a
| City Series ACV60E
62
ACB40E/ACC40LE/ACC40RE/ACV40AC/ACB60E/ACV60E
GENERAL INFORMATION
The Fan Kit increases the effectiveness of your
fireplace by dispersing warm air to remote locations
in the same room or other rooms in your home.
Up to two kits may be installed on the fireplace.
Important Installation Notes
1. The appliance installation must conform with local
codes and installation codes.
2. The appliance when installed, must be electri-
cally grounded in accordance with local codes.
3. This kit is tested and safe when installed in ac-
cordance with this installation manual. Please
read all instructions before starting installation
and follow them carefully during installation.
4. Installation of this kit must be performed by a
qualified service technician.
5. The Fan Kit must be installed only as specified.
Any modifications of the kit or components will
void the warranty and may cause a fire hazard.
Floor
Register
6. Plan the location of the fireplace and the warm
air duct runs. See diagram 1 as a guide for duct
runs and locations.
Description
Aluminum Flex 4.5m
Duct Flange-Stove
Sidewall Grille
Connector Clamp
9
8
Maximum Duct Run: 9.0m
Flexible Duct Kit Contains 4.5m
1
If you require more than 4.5m please purchase the
Fan Duct Extension Kit.
NOTE: Airflow through the duct system is affected
by the duct length and number of bends. Keep
the length and bends to a minimum to maximize
performance.
MINIMUM FRAMING
CLEARANCES
*
Wall studs must be 407mm on center for mount-
ing fan housing.
* Fan Housing: Maintain a 6mm clearance from
fan housing to combustible material.
* Wall Registers must be 102mm above floor and
/ or 102mm below ceiling.
1. Determine the location of the air register/fan
housing assembly. Cut a 121mm x 406 mm hole
between framing members (wall studs or floor
joists). Maintain a 6 mm clearance from fan
housing to combustible material. See Framing
Clearances section.
MINIMUM FAN DUCT
CLEARANCES
The fan ducting requires a minimum of
25mm clearance to combustibles.
8
Wall
Register
Minimum 102 mm
from floor
Wall
Register
Minimum 102 mm
from ceiling