Charge Event Log; Figure 5- 7 Fault/Warning Log Data Screens - Webasto SVS300 Installation, Operation And Maintenance Manual

Mhe intelligent fast charging systems
Table of Contents

Advertisement

SVS-200
Fault/Warning Log
CLEAR
Fault Event 1
12:29 02/06/07
Fault Event 2
CLEAR
12:20 02/06/07
Fault Event 3
23:23 02/04/07
Fault Event
Log entry blank
CLEAR
Log entry blank
5.7

Charge Event Log

The charge event log data screens (see Figure 5- 8) allow the user to review the data from the
last 250 fast charge or equalization events performed by the charger. These data are stored in
the charger and are preserved even if power is removed from the charger.
1. Event ID screen - Shows the active (most recent) charge event. Using the UP and DOWN
arrow keys the user may scroll through the last 250 charge events. For each charge event,
the BMID number will be displayed to help the user locate a particular charge event. Once
the desired event is displayed, press ENTER to open the log for that event. Press CLEAR at
any point in the log to return to the Event ID screen.
2. Battery state screen - Shows the beginning and ending voltage, beginning and ending current,
and beginning and ending states of charge (SOC) for the selected charge event.
3. Charge date screen - Shows the date and time recorded at the beginning and end of the
selected charge event.
4. kWhrs Returned – Shows the cumulative kWhrs returned to the battery during the selected
charge event.
20153-W-03-01
IMPORTANT INFORMATION – SAVE THESE INSTRUCTIONS
ENTER
1
There are 50
Fault events
in a log
n
ENTER

Figure 5- 7 Fault/Warning Log Data Screens

Installation, Operation and Maintenance
To top level screens
CLEAR
ENTER
Warning Code: 119
BMID TempSensr Fail
Cleared
12:30 02/06/07
Idle
at time of fault
19
2