Coupling For Hv-Dc Supply; Figure 24: Coupling For Hv-Dc Supply (Counterpart For X3A); Table 21: Plug-In Connector Coding - KEB COMBIVERT T6APD Instructions For Use Manual

Table of Contents

Advertisement

CONNECTION Of THE POWER UNIT

4.3.1.4 Coupling for HV-DC supply

The following plug-in connection is not included in the scope of delivery. It is assembled
by the vehicle manufacturer or directly ordered from the specified manufacturer. It is
recommended to lay the HV-DC + and HV-DC - cables together. Only cables approved
by the manufacturer must be used.
Manufacturer data accessories
Connector manufacturer
Website
Name
Protection class
Connection cross section
Mating cycles
Coding connector
Tightening torque according to
manufacturer's specification
Preload force according to
manufacturer's specification
Figure 24:
Manufacturer part number
H2K101-W2A035B1-A
H2K101-W2A016B1-A
Table 21:
NOTICE
1 4 3 2
Contact
1
2
3
4
Coupling for HV-DC supply (counterpart for X3A)
Plug-in connector coding
The indicated article numbers are to be understood as an example.
Defect due to loose plug connection !
► A correct plug-in connection is only given when the plug connector
is plugged-in and screwed with tightening torque.
Rosenberger
www.rosenberger.de
HVR 200; Coupler with HVIL
IP6K9K, IPXXD, IPX8 (plugged in)
16 mm², 35 mm² (depending on the design)
≤ 50
A
4 Nm ± 0.4 Nm
< 75 N
Name
Description
HV-DC +
High voltage DC input +
HV-DC -
High voltage DC input -
HVIL_in
Is used to open the Interlock Loop
HVIL_out
Is used to open the Interlock Loop
Cable cross-section
35 mm
2
16 mm
2
63