Connection Of The Control; Assignment Of The Connector X1A - KEB COMBIVERT T6APD Instructions For Use Manual

Table of Contents

Advertisement

CONNECTION Of THE CONTROL

4.4 Connection of the control
The following information must be observed when connecting:
NOTICE

4.4.1 Assignment of the connector X1A

Parts data connector X1A
Connector manufacturer
Website
Name
Housing colour
Part No.
PIN
1
2
3
4
5
72
Interference due to inductive and capacitive coupling
► Lay control and power cable separately (about 10...20 cm distance);
Lay crossings in a right angle.
► Use twisted bus cable.
► Do not lay the cables for temperature monitoring of the motor (also
shielded) together with the control cables!
All connections of the connector X1A have "Safe isolation" in accordance with
DIN EN 61800-5-1
and
ISO
Name
Description
Low voltage – voltage supply 9-32 V electrical system
LV_DC_AUX
(KL30g – switched positive cable directly from the battery)
Electrical system ground
LV_GND
(KL31 – Negative wire directly from the battery or vehicle
ground)
CAN_H_0
CAN-High Port 0 (CAN 2.0)
CAN_L_0
CAN-Low Port 0 (CAN 2.0)
CAN_H_0
Connection of additional CAN clients to port 0
6469-3.
TE Connectivity
www.te.com
23-pole connector housing
black
1-776087-1
continued on the next page