CONNECTION Of THE CONTROL
4.4.1.1 Terminal 15 „Enable"
Terminal 15 "Enable" is used for modulation release of the COMBIVERT T6
connected inverter modules can start the operation.
PIN
Reference
potential
Digital inputs
Table 26:
Figure 34:
4.4.1.2 Specification of the CAN bus
Interface 0
CAN-high
CAN-low
Interface 1
CAN-high
CAN-low
Transmission speed
Potential separation
Bus termination
Differential resistance in re-
cessive state
Table 27:
74
Status 0
/ V
U
_low
max.
6
min.
0
Specifications of the input „Enable"
9
Connection of the input terminal 15 „Enable"
X1A.3
X1A.4
X1A.7
X1A.8
20, 25, 50, 100, 125, 250, 500, 1000 kbit/s adjustable
Galvanic isolation to the control potential.
120 Ω at both ends of the bus line;
at T6
APD
≥ 4 kΩ
Specifications of the CAN bus
X1A.9
X1A.2 (LV_GND)
/ mA
/ V
I
U
_low
_high
3
32
not defined
7
2
switchable by external jumper.
, i.e. the
APD
Status 1
/ mA
I
_high
20
7