OPERATING CONDITIONS
3.1.3.2 Electromagnetic compatibility
EMC emitted interference
Line-conducted interferences
Radiated emissions
Radiated broadband interferences
Radiated narrow band interfer-
ence
Interference Immunity
Electromagnetic fields
Cable-fed disturbances
Static discharges
Burst - Ports for process meas-
urement control lines and signal
interfaces
Burst -
Power supply interfaces / auxiliary
voltage < 60 V
Surge - auxiliary voltage < 60 V
Cable-fed disturbances, induced
by radio-frequency fields
Table 7:
Electromagnetic compatibility
36
Standard
Class
C1
DIN EN 61800-3
ECE R10:Rev.5
–
Vo 2015/208
DIN EN 61800-3
C1
ECE R10:Rev.5
–
Vo 2015/208
ECE R10:Rev.5
–
Vo 2015/208
Standard
Level
ECE R10:Rev.5
–
Vo 2015/208
10 V/m
DIN EN 61000-4-3
3 V/m
1 V/m
ECE R10:Rev.5
–
Vo 2015/208
8 kV
DIN EN 61000-4-2
4 kV
1 kV
DIN EN 61000-4-4
DIN EN 61000-4-4
2 kV
1 kV
DIN EN 61000-4-5
10 V
DIN EN 61000-4-6
Notes
–
–
–
62-52 dB (μV/m) 30...75 MHz
52-63 dB (μV/m) 75...400 MHz
63 dB (μV/m) 400 MHz...1 GHz
52-42 dB (μV/m) 30...75 MHz
42-53 dB (μV/m) 75...400 MHz
53 dB (μV/m) 400 MHz...1 GHz
Notes
–
80 MHz...1 GHz
1.4...2 GHz
2...2.7 GHz
–
AD (air discharge)
CD (contact discharge)
–
–
–
0.15...80 MHz