Dc Connection; Motor Connection - KEB combivert B6 Installation Manual

Table of Contents

Advertisement

Installation and Connection
3.3.3

DC connection

Input voltage 230 V-class: 250...370 V DC
Input voltage 400 V-class: 420...720 V DC
+
-
At DC supply pay attention to the permissible voltage range of the fuses !
3.3.4

Motor connection

Max. motor line length see „Technical data"
M
3~
ϑ
W
Apply shieldings over a large contact
surface of the mounting plate !
1) Motor temperature monitoring T1, T2 (the evaluation can be activated as described in
annex A.5)
Tripping resistance 1.65...4 kΩ
Reset resistance 0.75...1.65 kΩ
Design in accordance with VDE 0660 Part 302
Do not lay connecting cable together with control cable.
Permissible in the motor cable only with double shielding.
X1B
++
W
- -
Tightening torque 0.6 Nm (5 lb inch)
Connection cross-section 1.5...4 mm² (AWG 16-11)
PE
U
V
DC connection
Terminal strip X1B
X1B
U
V
W
T1
1)
T2
Tightening torque 0.6 Nm (5 lb inch)
Connection cross-section 1.5...4 mm² (AWG
++
– –
PB
U
– –
PB
++
U
++
– –
PB
U
V
– –
PB
V
++
U
Terminal strip X1B
16-11)
W
V
T1
T2
T1
T2
V
W
W
T1
T2
T1
T2
W