Chapter 6: Configuring the SA-100
Figure 6-1 Systems Parameters Page
6.2.4
Turn Off Port 5004
The SA-100 does not support using port 5004 for RTP audio transmissions.
Make sure that the option to use port 5004 for RTP is turned off:
Step 1 Launch ShoreWare Director.
Step 2 Click Administration > Call Control > Options. The Call Control Options
Step 3 Uncheck the Always Use Port 5004 for RTP check box.
Step 4 Click Save.
6.2.5
Add SA-100 to ShoreTel Site
After you have installed the SA-100 on the network, you must associate the unit with
a ShoreTel site. A ShoreTel site is defined as a region managed by a ShoreTel server.
You will need the following SA-100 information to associate the unit with a site:
IP address
•
Ethernet address
•
NOTE You can use the terminal emulation procedure described in
Address Manually" on page 35
NOTE If the SA-100 is installed inside the DMZ, be sure that routable traffic
between the DMZ and LAN is enabled and NAT is disabled.
ShoreTel 12.3
page appears.
SA-100 Planning, Installation, and Administration Guide
to obtain this information.
"Setting the IP
43