PrintMate A79510100 Issue 2

Output Error

Error Message / Symptom
Output error
50
Possible Cause
Cassette misfeed into Output
Drum.
Cassette caught on Output Chute
guides.
Remedy
Open Print Door.
Manually rotate Output
Drum and remove any
Cassettes.
Check that no Cassettes are
trapped under the Output
Drum or Conveyor block.
Use the Touch Panel or PC
to continue.
Check that Output Chutes
are correctly fitted and
realign if necessary (see
Chapter 3 - Connecting the
Output Chutes).
Check that the side-guides
on the Output Chute are
not bent inwards and
interfering with the Cassette
as it exits.