Chiller specifications

Learn the specifications required for the chiller used to cool the laser illumination source.
Characteristics
Coolant
Coolant temperature*
Coolant temperature stability
Laser cold start temperature
Warm up time
Coolant pressure
Coolant flow rate
* Always above dew point.
When the projectors are used in a projection array, the chiller specifications are between 19°C (66°F) to
22°C (71.6°F) with a 0.1°C stability.
Chiller cooling capacity
Light illumination source
Type A
Type C
Type D
Type E

Accessories

Learn about the accessories (sold separately) available for the projector.
Lenses
Lens type
DLP CINE 4K fixed
High brightness fixed
DLPCINE high brightness
zoom
Christie Eclipse Installation and Setup Guide
020-103331-01 Rev. 1 (04-2022)
Copyright
©
2022 Christie Digital Systems USA, Inc. All rights reserved.
Minimum
20% propylene glycol with additives, 80% distilled water
19°C (66°F)
19°C (66°F)
1.5 bar
20 liters/minute
4K
0.72:1
0.9:1
1.13-1.66:1
1.31-1.85:1
1.45-2.17:1
1.63-2.71:1
1.95-3.26:1
Typical
22°C (71.6°F)
0.1°C
5 minutes
Chiller cooling capacity
Built before January 1, 2020—5.5kW
Built after January 1, 2020—4.5kW
4.0kW
4.0kW
3.0kW
2K
1.0:1
1.25-1.83:1
1.45-2.05:1
1.6-2.4:1
1.8-3.0:1
2.15-3.6:1
Introduction
Maximum
25°C (77°F)
0.5°C
15 minutes
3.5 bar
Part number
144-110103-XX
38-809071-XX
108-342100-XX
108-335102-XX
108-336103-XX
108-337104-XX
108-338105-XX