Light Intensity Hazard Distance - Christie Eclipse Installation And Setup Manual

Table of Contents

Advertisement

Warning! If not avoided, the following could result in death or serious injury.
This product must be installed within a restricted access location not accessible by the general
public.
The installation setup must prevent access to the nominal ocular hazard area.
Only Christie qualified technicians who are knowledgeable about the hazards associated with
laser use, high-voltage, and high temperatures generated by the product are authorized to
assemble, install, and service the Christie Laser Projection System.
UV EXPOSURE! Protective UV safety glasses with side shields and Christie approved protective
safety clothing must be worn when performing optical adjustments or servicing the product.
EXTREME BRIGHTNESS! Do not place reflective objects in the product light path.
LASER RADIATION! Do not look into the end of a fiber optic cable while the product is
operational.
Invisible infrared LED radiation might be emitted from disconnected fibers or connectors. Do not
stare into beams or view directly with optical instruments.
Lasers contain a high energy density, which can be dangerous for skin tissue as well as pose an
electrical, chemical, and non-ionizing radiation hazard.
RADIATION HAZARD! Incorrectly attached cables may result in hazardous radiation exposure.
Caution! If not avoided, the following could result in minor or moderate injury.
Before inspecting the fiber optic cable, turn off the laser module breakers.
RADIATION HAZARD! Use of controls or adjustments, or performing procedures other than those
specified may result in hazardous radiation exposure.
Adjust boresight with low light levels from a single laser module.

Light intensity hazard distance

This projector has been classified as Risk Group 3 as per the IEC62471 standard due to possible
hazardous optical and thermal radiation being emitted.
Warning! If not avoided, the following could result in serious injury.
PERMANENT/TEMPORARY BLINDNESS HAZARD! No direct exposure to the beam must be
permitted. Class 1 Laser Product - Risk Group 3 according to IEC 60825-1:2014 and IEC
62471-5:2015.
PERMANENT/TEMPORARY BLINDNESS HAZARD! Operators must control access to the beam
within the hazard distance or install the product at the height that prevents exposure of
spectators' eyes within the hazard distance. The hazard zone must be no lower than 3.0 meters
above the floor and the horizontal clearance to the hazard zone must be a minimum 2.5 meters.
EXTREME BRIGHTNESS! Do not place reflective objects in the product light path.
The following show the zones for ocular and skin hazard distances.