Installation instructions│ T24│ Annex A: List of errors and error messages
Event code
StopButtonAdcInvalidValue (1162)
StopButtonInconsistentBranchesDetectedByCpu2
(1163)
SafetyErrorRs485Cpu2CannotOverrideDe
(1164)
SafetyErrorRfActiveWhenProhibited (1165)
SafetyErrorCPU1VsCPU2SafeDataInconsisteny
(1166)
SafetyErrorRfPowerActiveWhenNotAllowed
(1168)
SafetyErrorCpu1DetectedSeqNrOutOfSync
(1169)
SafetyErrorCpu2DetectedSeqNrOutOfSync
(1170)
SafetyCrcErrorInSettingsBlock (1171)
StopButtonInconsistentBranchesDetectedByCpu1
(1172)
84
Event description
[ The AD converter used to
measure the stop button state
measured an invalid value ]
[ According to CPU2 the two
branches of the stop button
does not agree about the
state of the stop button ]
[ CPU2 could not override
CPU1 RS485 driver enable. RX
was low xxxx times when doing
break from CPU1 (majority
should be high, see code) ]
[ The RF (cc2520) clock was
activated by CPU1 when it was
not allowed to ]
[ CPU1 and CPU2 does not
agree on the state of the
safe data ]
[ The RF power is on while it
shall not be ]
[ The sequence number sent
from CPU2 to CPU1 was
considered out of sync by
CPU1 ]
[ The sequence number sent
from CPU1 to CPU2 was
considered out of sync by
CPU2 ]
[ Settings block id xxxx had
safetyCRC xxxxxx, expected
xxxxxx ]
[ According to CPU1 the local
ES2 branch and the ES1 branch
from CPU2 are inconsistent ]
Category
2hw
2hw
2hw
1
1
1
1
1
2sm
2hw
IM-PM-TX101-EN-v08