Altitude And Air Pressure; Alternating Temperature And Humidity; Expanded Operation Temperature; Expanded Operation Temperature Limits - Inspur NF5180M6 User Manual

Hide thumbs Also See for NF5180M6:
Table of Contents

Advertisement

8.3

Altitude and Air Pressure

Table 8-3 Altitude and Air Pressure
Parameter
Condition
Operating
Altitude
Transportation
(Storage)
8.4

Alternating Temperature and Humidity

Table 8-4 Alternating Temperature and Humidity
Parameter
Condition
Operating
Humidity
Transportation
(Storage)
8.5

Expanded Operation Temperature

The system performance will be impacted when the temperature is not
within the specification range;
Ignore alarm sound of ambient temperature when the temperature is not
within the specification range.
Table 8-5 Expanded Operation Temperature
Temperature Specification
5℃ - 40℃ (5% - 85%RH)
-5℃ - 45℃ (5% - 90%RH)
8.6

Expanded Operation Temperature Limits

Powering on under 5℃ is not allowed
The altitude cannot be higher than 3,000 m (9,843 feet)
CPU higher than 165 W is not supported
Requirement
0 to 3,048 m (0 to 10,000 feet)
0 to 12,192 m (0 to 40,000 feet)
Requirement
Relative humidity is 5% to 90% with
maximum dew point at 38°C (100.4°F)
Relative humidity is 5% to 93% with
maximum dew point at 39°C (102.2°F),
and the air must be non-condensing
all the time
Note
Continuous running is possible
1
Running time ≤1% per year
2
73