Altitude and Atmospheric Pressure

Table 11-3 Altitude and Atmospheric Pressure
Item
Status
Operating
Altitude
Transportation (Storage)

Alternating Temperature and Humidity

Table 11-4 Alternating Temperature and Humidity
Item
Status
Operating
Humidity
Transportation
(Storage)

Extended Operating Temperature

Table 11-5 Extended Operating Temperature
Temperature Specifications (Example)
5°C to 40°C (5% to 85% RH)
–5°C to +45°C (5% to 90% RH)
Note 1: When the server operates beyond the defined temperature specifications, system performance
will be affected.
Note 2: When the server operates beyond the defined temperature specifications, ignore monitoring
alarms for the ambient temperature.
Limits of the Extended Operating
Temperature
The system cannot be started in an environment where the ambient
temperature is lower than 5°C.
The server cannot be used at an altitude higher than 3,000 meters.
CPUs with a power higher than 165 W are not supported.
Redundant power supplies are not supported.
Specifications
0 to 3,048 m (10,000 feet)
0 to 12,192 m (40,000 feet)
Specifications
Relative humidity: 5% to 90%.
Maximum dew-point temperature: 38°C (100.4°F)
Maximum dew-point temperature: 39°C (102.2°F).
Relative humidity: 5% to 95%, non-condensing
Description
Continuous operation
Note 1
≤ 1% of the runtime per year
Note 2
51