5. Set the battery age.
# raidutil -c cxtxd0s2 -R

SIMM Upgrade Procedure (A1000 only)

The following procedure provides instructions for upgrading the A1000 controller
board from the factory configured 24 Mbytes to an 80 Mbyte system.
Caution – Be sure to have an antistatic wrist strap and mat ready for the SIMMs
and the controller board.
1. Follow the procedure for removing the controller board from the system. See "To
Remove the Controller Board."
FIGURE 3-8
2. Flip the controller canister over so you can see the SIMM cover.
See the orientation of the SCSI ports.
3. Remove the two screws that hold the SIMM cover to the center of the controller
canister and remove the cover.
This exposes the SIMMs (
30
Sun StorEdge A1000 and D1000 Installation, Operations, and Service Manual • November 2002
A1000 Controller—Fully populated with 8 Mbyte and 4 Mbyte SIMMs
(factory configuration)
FIGURE 3-8
).
4 Mbyte
4 Mbyte
8 Mbyte
8 Mbyte