Battery Bypass

In the event of a battery failure, you can use the following battery bypass proce-
dure.
1.
Power down the pedestal and turn off the power supply in the rack.
2.
Remove the pedestal rear cover.
3.
Locate the back panel harness cables and identify the three in line Molex
connectors that are marked "S" "D" and "B".
4.
Disconnect the Power Supply Molex connector marked "S".
5.
Disconnect the Contact Block Molex connector marked "D". (Do not dis-
connect the battery harness marked "B")
6.
Connect the Power Supply Molex connector marked "S" (purple. black, red
wires) to the Contact Block Molex connector marked "D" (purple, black,
red wires).
7.
Disconnect the four pin square female Berg connector from the top of the
battery board on the back panel (located under the positive side of the bal-
ance meter).
8.
Use a jumper wire to connect pins 1 (white/brown) and 3 (brown/black) on
the four pin Berg connector.
9.
Replace the pedestal cover.
4-32
Bypassing the battery eliminates the ability to operate the
pedestal in the event of power loss to the unit. Prompt service
is essential to restore full operational capability.