Delta Electronics ASDA-B Series User Manual page 159

Asda-b series standard ac servo drive for general purpose applications
Table of Contents

Advertisement

Chapter 7 Servo Parameters|ASDA-B Series
Parameter
Name
P2-31■
AUT1
P2-32▲
AUT2
P2-33
Reserved
P2-34
SDEV
P2-35
PDEV
P2-36
OVL
P2-37
OVW
P2-38
GBIT
P2-39
Reserved
~ P2-43
P2-44
ATUR
P2-45
AFRQ
P2-46
ATME
P2-47■
ASTR
P2-48
CLRT
P2-49
SJIT
Explanation of symbols (marked after parameter)
(★)
Read-only register.
(▲)
Parameter cannot be set when Servo On (when the servo drive is enabled).
(●)
Parameter is effective only after the servo drive is restarted (after switching power off and on).
(■)
Parameter setting values are not retained when power is off.
7-6
Extension Parameters
Function
Auto Stiffness and Responsiveness
Level
Tuning Mode Selection
Overspeed Warning Condition
Excessive Error Warning Condition
Overload Protection Level
Output Overload Warning Level
Special Function
Motor Rotation Number
Motor Rotation Frequency
Motor Rotation Time
Auto-Tuning Start Function
Pulse Deviation Clear Mode
Speed Detection Filter and Jitter
Suppression
Control
Default
Unit
P
6
N/A
0
N/A
5000
rpm
3000
10pls
100
%
50%
N/A
0
N/A
2
turn
10
0.1Hz
15
sec
0
N/A
0
N/A
110
N/A
Revision January, 2009