Default Di Signals And Do Signals - Delta Electronics ASDA-B Series User Manual

Asda-b series standard ac servo drive for general purpose applications
Table of Contents

Advertisement

Table 3.F Default DI Signals and DO Signals
Signal
SON
ARST
GAINUP
CCLR
ZCLAMP
CMDINV
INHP
TRQLM
SPDLM
GNUM0
SPD0
SPD1
TCM0
TCM1
S-P
S-T
T-P
EMGS
CWL
CCWL
TLLM
TRLM
Signal
SRDY
SON
ZSPD
TSPD
TPOS
TQL
ALRM
BRKR
OLW
WARN
Revision January 2009
The factory default settings of DI signals
DI Code
01
Servo On
02
Alarm Reset
03
Gain switching in speed and position mode
04
Pulse clear
05
Zero speed CLAMP
06
Command input reverse control
07
Pulse inhibit input
09
Torque limit enabled
10
Speed limit enabled
11
Electronic gear ratio (Numerator) selection 0
14
Speed command selection 0
15
Speed command selection 1
16
Torque command selection 0
17
Torque command selection 1
Position / Speed mode switching (OFF: Speed, ON:
18
Position)
Speed / Torque mode switching (OFF: Speed, ON:
19
Torque)
Torque / Position mode switching (OFF: Torque,
20
ON: Position)
21
Emergency stop (contact b)
22
Reverse inhibit limit (contact b)
23
Forward inhibit limit (contact b)
25
Torque limit - Reverse operation
26
Torque limit - Forward operation
The factory default settings of DO signals
DO Code
01
Servo ready
02
Servo On
03
At Zero speed
04
At Speed reached
05
At Positioning completed
06
At Torques limit
07
Servo alarm (Servo fault) activated
08
Electromagnetic brake control
09
Output overload warning
10
Servo warning activated
Chapter 3 Connections and Wiring|ASDA-B Series
Function
Function
Default Settings
DI1
DI2
DI3
DI6
DI4
DI5
Default Settings
DO1
DO2
DO3
3-17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents