Off Delay Time Of Electromagnetic Brake - Delta Electronics ASDA-B Series User Manual

Asda-b series standard ac servo drive for general purpose applications
Table of Contents

Advertisement

P1 - 43
MBT2

OFF Delay Time of Electromagnetic Brake

Default: 100
Applicable Control Mode: P/S/T
Unit: ms
Range: -1000 ~ 1000
Settings:
Used to set the period of time between when the servo drive is Off (Servo Off) and when
electromagnetic brake output signal (BRKR) is unactivated.
NOTE
1) When the setting value of P1-43 is higher than or equal to 0(zero)
SON
(DI Input)
BRKR
(DO Output)
When Servo Off (the servo motor is disabled), the BRKR output will be Off after the Off delay
time set by P1-43.
2) When the setting value of P1-43 is lower than 0(zero)
SON
(DI Input)
SON
(DO Output)
BRKR
(DO Output)
When Servo Off (the servo motor is disabled) and the BRKR output is also Off, the servo
drive will be Off after the Off delay time set by P1-43.
Revision January, 2009
ON
OFF
ON
OFF
MBT1
(P1-42)
ON
OFF
OFF
OFF
MBT1(P1-42)
Chapter 7 Servo Parameters|ASDA-B Series
Communication Addr.: 012BH
Related Section:
DO BRKR(08) in Table 7.B
P1-42, Section 6.6.4
MBT2
(P1-43)
ON
MBT2(P1-43)
ON
OFF
OFF
OFF
OFF
OFF
7-35