Check Cooking Chamber; Cooking Chamber; Lighting - Henny Penny FlexFusion FPG-221 Maintenance Instruction

Gas platinum combi incl. grease collection
Table of Contents

Advertisement

8.5 Check cooking chamber

8.5.1 Cooking chamber

Check the cooking chamber for contamination
Test criteria
• Cooking chamber is clean.
If No
Inform the operator, because the proper function of the unit cannot be reliably checked and guaranteed due to the
contamination.
Check the cooking chamber for limescale residues
Test criteria
• Cooking chamber is free of limescale residues.
If No
Decalcify unit and check on-site softening system. Check water quality.
Check drain screen
Test criteria
• Drain screen is present and screwed to the drain?
If no,
mount drain screen.
NOTICE

8.5.2 Lighting

Check the lighting of the cooking chamber
Test criteria
• Lighting cooking chamber works.
• Glass cover of the lamp is clean.
If No
Replace bulb.
If No
Clean glass.
3. Clean unit with spray bottle and liquid cleaner. Spray the liquid
cleaner completely into the steam outlet nozzle using a spray bottle
and allow it to take effect.
Rinsing with water is not necessary.
4. Wipe the steam outlet nozzle dry.
Material damage due to missing drain screen
Operating the device without drain screen may cause damage to the device.
• Only operate the device with the drain screen screwed on.