3.2.3

Tools You Will Need

Before you start the installation, make sure that you have all the necessary equipment at hand.
Usage
General
Shelf
Grounding
AC PSU
DC PEM
System Access
3.2.4

Torque Values

In the following table you can find information on the torque values that you have to use while
handling and maintaining the system.
Table 3-1 Torque Values
For...
Ground nuts
Pluggable screw terminals
Captive screws on MF106
Thumb screws for FRUs
Thumb screws on AdvancedTCA blades
54
Equipment
Phillips head screwdriver #1 and #2
Wrenches (7, 8, 10 mm or 0.28, 0.31, 0.39 inch)
Large, medium and small Phillips screwdrivers
Antistatic mat
ESD wrist strap
Transport equipment: Hand truck or forklift/pallet truck
Lifting equipment for installation
Earth grounding cable with a two-hole lug, distance 5/8" (15.9 mm)
Note: Grounding cable of size 1.25mm
system
Power input cables with a minimum cross section of 1mm
Power input cables with a minimum cross section of 2.5 mm
Crossover cable
Twisted pair Ethernet cable
CAT-5
Value in N m
2.5
0.6
0.6
0.6
0.6
Centellis 2000 Shelf Release 3.0 Installation and Use (6806800L99F)
2
for AC system, and 2.5 mm
2
2
, AWG 12
2
for DC