Power-On After Blade Insertion; Figure 11-1 Blade Power-On After Insertion - Emerson Centellis 2000 Shelf Release 3.0 Manual

Table of Contents

Advertisement

11.3.1 Power-On After Blade Insertion

The default for each slot is that when a blade is inserted it is automatically switched on by the
shelf manager. To change this, you need to change the shelf FRU information via the HPI FRU
activation control. The default for the Auto Insert Timer in HPI is 60 s.
Figure 11-1
START
Start Insertion
Timer
Shelf manager
controlled activation
Auto Insert Timer
in HPI
< 8
Stop timer
Customer
application
decides what to do
FINISH
Centellis 2000 Shelf Release 3.0 Installation and Use (6806800L99F)
Blade Power-On After Insertion
Yes
Stop Insertion Timer
No
Wait for Insertion Timer
Yes
to expire or issue an HPI
Hotswap Control request
No
No
Insertion Timer has
Shelf manager
powers on the
Yes
HPI powers on the
expired
Software
blade
blade
151