Emerson Lumity XWEB5000 PRO Installing And Operating Instructions

Emerson Lumity XWEB5000 PRO Installing And Operating Instructions

Advertisement

Quick Links

XWEB5000 PRO
(V.1.0)

Advertisement

Table of Contents
loading

Summary of Contents for Emerson Lumity XWEB5000 PRO

  • Page 1 XWEB5000 PRO (V.1.0)
  • Page 2: Table Of Contents

    TABLE OF CONTENTS PRODUCT DISPOSAL (WEEE) ....................... 4 THE RECIPIENTS OF THIS MANUAL ..................... 4 PACKAGE ..............................5 TECHNICAL DATA ........................... 6 INSTALLATION ............................7 XWEB ..............................7 CONTROLLERS ..........................9 5.2.1 CONFIGURATION FOR XC400/600/800/900 and XH200/300/400 SERIES ......11 5.2.2 CONFIGURATION FOR XJA/XJP/XJM MODELS ..............
  • Page 3 CAUTION: TO PREVENT FLAMES FROM DEVELOPING OR ELECTRIC SHOCK, AVOID ANY CONTACT BETWEEN THIS DEVICE AND RAIN OR WATER CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE THE COVER IT DOES NOT CONTAIN ANY PARTS THAT REQUIRE SERVICING BY THE USER ALWAYS HAVE QUALIFIED STAFF PERFORM THE PROCEDURES.
  • Page 4: Product Disposal (Weee)

    CAUTION The customer shall bear full responsibility and risk for product configuration in order to achieve the results pertaining to installation and/or final equipment/system. Upon the customer's request and following a specific agreement, Dixell s.r.l. may be present during the start-up of the final machine/application, as a consultant, however, under no circumstances can the company be held responsible for the correct operation of the final equipment/system.
  • Page 5: Package

    PACKAGE Before opening the package make sure that the packaging is intact and that there is no sign of impact or tampering. Before starting any operation, it is necessary to check that the XWEB box contains: • 1 XWEB 5000 PRO unit •...
  • Page 6: Technical Data

    TECHNICAL DATA Power supply 100-230 V Power 60 W Voltages and maximum current applicable to the AUX1-2-3 AUX terminals 1-2-3 AUX1 AUX2-3 Operating conditions (temperature, humidity, 0/45°C R.H.5÷95% (non-condensing) special conditions) Electrical safety LVD - COUNCIL DIRECTIVE 2014/35/EU Electromagnetic compatibility EMC - COUNCIL DIRECTIVE 2014/30/EU Rechargeable and non-removable lithium battery.
  • Page 7: Installation

    INSTALLATION XWEB For installation, the XWEB system must not be opened in any way. If the box is opened, the warranty will lapse. XWEB can be installed in various ways based on the type of user interface access that you wish to provide for the final user.
  • Page 8 Colour Description Green On when the system is powered Blue On when the disc executes physical writing operations Blue On when the system is recording data Ser1/Ser2 Blue On when the system is reading and/or writing on serial port 485 Blue On when the system runs operations with the analogue modem DI1/DI2...
  • Page 9: Controllers

    CONTROLLERS XWEB has at least one RS485 serial port, on which the line of the controller devices can be connected. If there are more serials, more device lines can be served. Most Dixell controller devices are equipped with an RS485 serial output and can be connected without the need for any additional module or connection cable.
  • Page 10 • Do not branch into the line: Correct Mistaken • Keep the serial cable away from power cables and any possible source of electromagnetic disturbance. Mount the supplied ferrites on the serial ports as shown in the figure • Do not connect the shield of the serial cable to the earth of the electrical system •...
  • Page 11: Configuration For Xc400/600/800/900 And Xh200/300/400 Series

    On the same line, each controller is normally programmed with its own unique serial address, through the Adr parameter. Refer to the installation manual of the instrument itself for the access and modification procedure. To obtain a simple description of the categories to which they belong, divide the programming of the addresses progressively.
  • Page 12: Local Connectivity

    LOCAL CONNECTIVITY Local access with a screen, mouse and keyboard directly connected to the XWEB is the most common and most frequently used type of access for the user interface. The system can work even without these peripherals connected and it is possible, for example, to use this mode only for the initial configuration of the system;...
  • Page 13: Desktop Software Requirements (Pc)

    The terminal used must comply with and support the minimum characteristics for the installation and use of the following software. DESKTOP SOFTWARE REQUIREMENTS (PC) Browser Support Minimum Version Microsoft Edge SUPPORTED Mozilla Firefox SUPPORTED Google Chrome SUPPORTED Apple Safari SUPPORTED 10.1+ Opera SUPPORTED...
  • Page 14: Connectivity With Cross Cable

    CONNECTIVITY WITH CROSS CABLE Local access from the PC is the fastest way to manage setup. It is possible to connect a PC to XWEB through the network interface supplied with an ‘RJ45 Ethernet connector’. The connection between the two must be set up using a cross network cable (aka 'cross cable').
  • Page 15 1592010820 XWEB5000 PRO STP GB r1.0 18.03.2022.docx XWEB5000 PRO 15/20...
  • Page 16: Intranet Connectivity ("Or Lan Connection") And Vpn

    INTRANET CONNECTIVITY (“OR LAN CONNECTION”) AND VPN This type of connection will allow you to access XWEB from any PC connected to the local network. This type of connection must also be used to configure the XWEB for connection from the internet via VPN (Virtual Private Network).
  • Page 17: Internet Connectivity On Public Ip

    entering the XWEB IP address in the address bar. The default address is: http://192.168.0.200. Store the address in the list of favorites. INTERNET CONNECTIVITY ON PUBLIC IP This type of connection will allow you to directly access XWEB from any PC connected to the internet without having to install - on your PC - any additional software.
  • Page 18: Wifi Connectivity

    WIFI CONNECTIVITY This type of connection will allow you to directly access XWEB from a device equipped with a Wi-Fi connection, or to allow XWEB to access an already configured Wi-Fi network. A prerequisite for these types of connectivity is the installation of the WIFI dongle in the XWEB USB port. ATTENTION: Only use dongles officially supported by this monitoring unit.
  • Page 19: Operative Procedures

    ___________________________ 10. TRADEMARKS Consider It Solved and Intelligent Store are trademarks and Emerson Climate Technologies and the Emerson Climate Technologies logo are service marks and trademarks of Emerson Electric Co. Windows and Internet Explorer are registered trademarks of Microsoft Corporation in the United States and other countries.
  • Page 20: Notes

    11. NOTES ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ 1592010820 XWEB5000 PRO STP GB r1.0 18.03.2022.docx XWEB5000 PRO 20/20...

This manual is also suitable for:

Lumity xweb1000d pro

Table of Contents