Network Management and System Access
GATEWAY=
Heartbeat Addresses
The ppp0 and ppp1 serial links are used for the heartbeat interfaces between Shelf
Managers. The addresses can be modified by changing the values associated with
HB1_BASE and HB2_BASE.
HB1_BASE=192.168.101.0
HB2_BASE=192.168.102.0
The last octet is obtained from the SLOT value, so only the first three octets are configurable.
Switch Slot IP Addresses
The C2000 shelf does not use the SWITCH_SLOT_IPADDR variable.
8.3.4

Restoring Factory Settings

To restore factory settings:
1. Login either through the serial port, or by using ssh to the Shelf Manager.
2. Remove everything in the persistent file area. For example:
cd /usr/local , rm -rf *
3. Reboot the Shelf Manager.
Shelf Manager boots up using the factory settings.
This does not include the Shelf IP addresses or Shelf Geographical Address stored in the Shelf
FRU data.