8.2.2 N4KB2
N4KB2
1
(a)
Operation classification Solenoid valve
(a) Operator type
Code
Description
1
2-pos.single operator
2
2-pos.double operator
3
3-pos.all ports blocked
4
3-pos.load ports open to exhaust ports
5
3-pos.load ports open to supply ports
(d) Electric connection
Code
Description
No code Grommet with lead wire
B
Small terminal box
Small terminal box, with indicator
L
light
Small terminal box,
LS
with surge suppressor and indi-
cator light
C
C00
C01
Plug-in connector C type
C02
C03
C1
C2
C20
Plug-in connector C type
C21
with surge suppressor and indi-
C22
cator light
C23
C3
D
D00
D01
Plug-in connector D type
D02
D03
D1
D2
D20
Plug-in connector D type
D21
with surge suppressor and indi-
D22
cator light
D23
D3
NOTE: Following options are available as a custom order.
・Ozone-proof specifications
Available in ozone-proof specifications by adding -P11 to the end of model number. Model number: ※※-Voltage-P11
・Coolant proof specifications
Selectable with option symbol A. Model number: ※※-A-Voltage
・Copper and PTFE free (Copper and PTFE materials are not used for flow path)
Available in copper and PTFE free by adding -P6 to the end of model number. Model number: ※※-Voltage-P6
0
H6
M1 B
(b)
(c)
(b) Port size
Code
H6
φ6 push-in joint
H8
φ8 push-in joint
H10
φ10 push-in joint
Lead wire
300mm
No option
No option
No option
300mm
500mm
1000mm
2000mm
3000mm
No option
300mm
500mm
1000mm
2000mm
3000mm
No option
300mm
500mm
1000mm
2000mm
3000mm
No option
300mm
500mm
1000mm
2000mm
3000mm
No option
−38−
S
AC100V
(d)
(e)
(c) Manual operating device
Description
Code
No code
M1
(e) Other options
Code
No code No option
Surge suppressor attached
S
(Only grommet with lead wire)
(f) Voltage
Code
AC100V
AC100V 50/60Hz
AC200V
AC200V 50/60Hz
DC24V
DC24V
AC24V
AC24V 50/60Hz
AC110V
AC110V 50/60Hz
AC115V
AC115V 50/60Hz
AC120V
AC120V 50/60Hz
AC220V
AC220V 50/60Hz
DC12V
DC12V
 The attached surge suppressor is suppression type (Diode)
only for the grommet with lead wire of below DC 24V.
 If DC voltage type is selected for (f), L will be provided
with a builtin surge suppressor for DC voltage.
 The AC100 and 200V coil can be used for AC110V (60Hz)
and AC220V (60Hz), respectively.
SPECIFICATION
HOW TO ORDER
(f)
Description
Non-lock type manual operating
device
Lock type manual operating
device
Description
Description
Standard
Option
[SM-213928-A/2]

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MN4KB2 Series and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents