4
INSTALLATION
3) Wiring of the small terminal box (B)
Wire the terminal box by following ① to ⑥ in the illustration.
② Terminal caulking
Crimp terminal (Parts No. 4K9-013)
Caulking tool (Tyco Electronics Japan 720781-3)
Case (Selective 4-position
in 90°apart available)
Tightening torque
0.3〜0.4N・m
Cap
Tightening torque
1.65〜2.5N・m
⑤ Place the case over the tip of pin support and
Top rib
[SM-213928-A/2]
Pin support
③ Insert caulked terminals
Gasket
Screw
Washer
⑥ Tighten the cap after placing
a gasket and washer.
tighten the screw.
Note : Hook the top rib of pin support to the
hole edge of the case as per illustrated below.
Case
Length
Pin support
lead wire
④ Slide the gasket and pin support over
live terminals and earth terminal.
Earth terminal
Gasket
to the pin support
Direction of the case as
per illustrated above or
180° opposite.
8
of
―21―
Coil
Live terminals
(Unnecessary to distinguish plus or minus)
Lead wire
(0.3 to 0.75mm
)
2
① Peeling a seal of lead wire
(Refer of the following table
as for the cutting length of cord.)
Cabtyre cord
JIS C3306VCTF 2-cord,
Outside diameter φ4 to 6.5
Direction of the case 90°
to the right or left off per
illustrated as above
13
4
Need help?