Intelligent Peripheral Management Controller
The following table provides the feature set supported with ATCA-8310:

Table 7-14 Feature Selector Assignments

Feature Selector
E0h
E1h

7.22.4 Get Feature Configuration

This command can be used to retrieve the IPMI feature set being configured.

Table 7-15 Get Feature Configuration Command

Byte
Request Data
1
2
3
4
Response Data
1
2
3
4
5
6
242
Description
FAILSAFE Function Enable/Disable
Select FPGA flash
Data Field
LSB of Emerson IANA Enterprise Number. A value of CDh shall be used.
2nd byte of Emerson IANA Enterprise Number. A value of 65h shall be used.
MSB of Emerson IANA Enterprise Number. A value of 00h shall be used.
Feature Selector
Completion Code. Generic plus the following command-specific completion
codes:
80h = feature selector not supported.
LSB of Emerson IANA Enterprise Number. A value of CDh shall be used.
2nd byte of Emerson IANA Enterprise Number. A value of 65h shall be used.
MSB of Emerson IANA Enterprise Number. A value of 00h shall be used.
Feature Configuration
00h = disabled (Feature Selector = E0)
01h = enabled (Feature Selector = E0)
02h = restore factory default (golden) (Feature Selector = E1)
C0h = reload selected FPGA image (Feature Selector = E1)
C1h = enabled and activated (Feature Selector = E0)
03h - FFh = reserved
Persistency / Duration