Table 8-179 Test Pattern Comparator Link And Timeslot Register Register - Emerson ATCA-8310 Manual

Table of Contents

Advertisement

8.4.2.3
TSIP Interface Test Pattern Comparator Block ( TstPatCmpBlk)
Resets:
Pwr = Power On Reset
Soft = Soft Reset
The TstPatCmp can be enabled to receive either static pattern or pseudo random pattern from
a remote generator. The Source can be a DSP or the Ser2TSIP block. The TSIP link is selectable
between 0 and 59. The TSIP receive timeslot is selectable between 0 and 511. The
TstPatCmpBlk includes a PRBS pattern comparator (eleven stage LFSR with taps at the 9th and
11th stage). The pattern comparator is able to synchronize itself to the receive bit stream.
After synchronization 125 μs-frames and errors are counted. A time of 125us delay has to be
taken into account, til the comparator has stopped after resetting TstPatCmpRxPatEn bit in
TstPatCmpCtrlReg.
8.4.2.3.1 Test Pattern Comparator Link and Timeslot Register
Address: 0x60, TstPatCmpLnkTsReg
Width: 16 bit
This registers selects timeslot TSIP-link for the test pattern reception.
Table 8-179 Test Pattern Comparator Link and Timeslot Register
Bit
15...10
9
8...0
8.4.2.3.2 Test Pattern Comparator Receive Data Register
Address: 0x62, TstPatRcvDatReg
Width: 8 bit
ATCA-8310 Installation and Use (6806800M72D)
Acronym
Type
TstPatCmpLinkNo
RW
-
-
TstPatCmpTsNo
RW
Description
Selects the transmit Link
0..59, (60..63 will be same
as 0)
reserved
Selects the receive
timeslot (0..511)
CPLD and FPGA
Default
Pwr
Soft
0x0
X
X
undef
-
-
0x0
X
X
389

Advertisement

Table of Contents
loading